Troubleshooting

How to test and clean interconnected smoke alarms

Monthly testing, checking every alarm joins in, cleaning intervals by state, and a yearly routine.

General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.

Short answer

Test smoke alarms once a month by pressing and holding the test button until the alarm sounds. With interconnected alarms, check every other alarm sounds too, and repeat from each alarm. Vacuum the outside with a soft brush every 6 to 12 months depending on your state's advice. Change any 9 volt battery yearly, and replace every alarm 10 years after it was made.

How often should I test smoke alarms?

Every fire service I checked says monthly: QFD [QFD fact sheet], Fire and Rescue NSW [FRNSW maintenance], the CFA [CFA maintenance], DFES [DFES], the SA MFS [MFS], ACT Fire & Rescue [ACT ESA], Tasmania Fire Service [TFS fact sheet] and AFAC [AFAC].

The legal minimum is lower. Queensland and NT tenants must test at least once every 12 months [Fire Services Act 1990 (Qld)] [NT Fire and Emergency Regs], Tasmanian tenants every 6 months [Tas Smoke Alarms Regs 2022], and Victorian and NSW landlords at least yearly [Vic RTA s 68AA] [NSW Fair Trading]. Monthly is the habit that actually catches a dead alarm.

How do I test a smoke alarm?

  1. Tell everyone in the house first. It is loud.
  2. Press and hold the test button. Fire and Rescue NSW says hold it "for at least five seconds until you hear the beeps" [FRNSW maintenance]. DFES says up to 10 seconds [DFES].
  3. Release once it sounds.
  4. If it doesn't sound, replace the battery (if it has a replaceable one) and test again. If it still fails, replace the alarm. Queensland law says an owner must immediately replace an alarm that doesn't operate when tested [Fire Services Act 1990 (Qld)].

Use a broom handle if you can't reach safely. Some ranges sell a wall controller or remote that tests without a ladder [PSA brochure].

How do I test interconnected smoke alarms?

Press test on one alarm and walk the house to check every other alarm is sounding. Then do the same from each alarm in turn. The SA MFS says to "ensure all interconnected smoke alarms activate at the same time when any one of the test buttons is pressed" [MFS]. Clipsal's instructions for its 240 volt alarms say to test each interconnected unit one by one and, for each test, ensure all interconnected alarms operate [Clipsal manual].

If one alarm doesn't join in, it may have dropped out of the wireless network or have a wiring fault. Follow the maker's pairing steps, or call an electrician for hardwired systems.

How do I clean a smoke alarm?

Vacuum around the vents with a soft brush attachment. Don't open the case, and never paint over an alarm. QFD says "clean away dust and insects with a vacuum or brush", "do not block or cover them" and "never paint over smoke alarms" [QFD fact sheet]. Clipsal's instructions suggest inspecting monthly for dirt, dust and insects, vacuuming or brushing as needed, and wiping around the alarm with a cloth lightly sprayed with insect surface spray every 3 to 6 months [Clipsal manual].

How often should I clean smoke alarms?

Cleaning interval by fire service
Fire serviceClean or vacuum
Fire and Rescue NSWEvery six months [FRNSW maintenance]
SA MFSEvery six months [MFS]
ACT Fire & RescueEvery six months [ACT ESA]
FRV and CFA (Victoria)At least once a year [FRV] [CFA maintenance]
DFES (WA)Every year [DFES]
AFAC (national)Regularly, including a vacuum at least once a year [AFAC]

If you live somewhere dusty or buggy, the six-monthly interval makes more sense.

When should I change the battery?

  • 9 volt (alkaline or lead): every 12 months, or when it chirps [FRNSW maintenance] [MFS]. That includes the 9 volt backup in many 240 volt alarms.
  • Sealed 10-year lithium: never. Replace the alarm when it signals end of life. See 10-year lithium alarms.

A simple yearly routine

  1. Monthly: press test on one alarm and check they all sound.
  2. Every six months: vacuum every alarm; test from each alarm in turn.
  3. Yearly: change any 9 volt batteries; check every manufacture date.
  4. At 10 years from manufacture: replace the alarm [AFAC].

Pick a date you'll remember. Clipsal ships calendar reminder stickers with some alarms and suggests changing the backup battery on a memorable day each year [Clipsal manual].

If the alarm is chirping, see chirping and beeping. If it keeps going off, see keeps going off.

Sources

Every source below was read on the official page. Last checked: November 2026.

  1. Queensland Fire Department: Smoke alarm laws are changing in Queensland (fact sheet QFE00206, PDF)
  2. Fire and Rescue NSW: Smoke alarm maintenance guide
  3. Country Fire Authority (Victoria): Smoke alarm maintenance
  4. Department of Fire and Emergency Services WA: Smoke alarms
  5. SA Metropolitan Fire Service: Smoke alarms fact sheet
  6. ACT Emergency Services Agency (ACT Fire & Rescue): Smoke alarms
  7. Tasmania Fire Service: Home fire safety fact sheet: smoke alarms (PDF, 2026 v4)
  8. AFAC (National Council for fire and emergency services): Smoke alarms in domestic and residential accommodation, guideline v4.0 (October 2023)
  9. Queensland Legislation: Fire Services Act 1990, Part 9A, ss 147W to 148K (PDF, current as at 6 December 2025)
  10. NT Legislation: Fire and Emergency Regulations 1996 (NT), Part 2A (reprint as in force at 16 July 2024, PDF)
  11. Tasmanian Legislation: Residential Tenancy (Smoke Alarms) Regulations 2022 (Tas)
  12. Victorian Legislation: Residential Tenancies Act 1997 (Vic), authorised version 111, section 68AA (PDF)
  13. NSW Government (NSW Fair Trading): Smoke alarms in a rental property
  14. PSA Products (Lifesaver): Lifesaver 6000 series brochure (PDF, hosted by Sparky Direct)
  15. Clipsal by Schneider Electric: 755PSMA4 photoelectric smoke alarm instruction sheet (PDF, copy hosted by Sparky Direct) (manufacturer instructions for one 240 V model)
  16. Fire Rescue Victoria: Smoke alarms (page updated 9 September 2026)