Rentals and sales

Landlord smoke alarm obligations in every state

Every state's landlord duties side by side: standard, testing, batteries, repairs and fines.

General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.

Short answer

Every Australian landlord must provide working smoke alarms that meet AS 3786, but the detail differs a lot by state. Queensland requires interconnected photoelectric alarms in every bedroom, tested and cleaned within 30 days before each tenancy or renewal. NSW and Victoria require at least yearly checks. WA requires mains-powered alarms under 10 years old. Tasmania bans 9 volt alarms in rentals. The NT requires photoelectric alarms at each new lease.

What are landlords' smoke alarm obligations in each state?

Landlord smoke alarm duties by state (summary)
StateAlarm standard for rentalsLandlord checksWho changes batteries
QLDPhotoelectric, no ionisation, interconnected, hardwired or 10-year sealed, every bedroom (since 2022 for leases)Test, clean and replace flat batteries within 30 days before each tenancy or renewalTenant during the tenancy
NSWAS 3786 on every levelCheck every year; repair within 2 business daysLandlord (tenant may choose to replace a removable battery)
VICPer building date (hardwired after 1997)Test at least every 12 months (since 25 Nov 2025); fix as an urgent repairLandlord must keep batteries fitted; anyone can change one
WAMains powered (limited 10-year exceptions), under 10 years, interconnected unless permit applied for before 1 May 2015Keep compliant throughout the tenancyTenant changes an easily accessible 9 V battery
SAAS 3786 placed to warn bedroomsNo fixed interval; CBS recommends testing at each routine inspectionLandlord (tenant clauses unenforceable)
TASMains with backup or 10-year non-replaceable; no 9 V alarmsTest on the first day of each tenancyNot applicable to sealed alarms; tenant tests every 6 months
ACTAS 3786, battery or hardwired, every storey and bedroom hallwayInstall and maintain; must be in place before the leaseTenant
NTPhotoelectric, hardwired or sealed 10-yearTest, clean, replace within 30 days before each tenancy; give written instructionsTenant replaces standby batteries in wired alarms

Sources: QLD [Fire Services Act 1990 (Qld)] [RTA], NSW [NSW Fair Trading], VIC [CAV] [Vic RTA s 68AA], WA [WA Building and Energy] [WA Consumer Protection], SA [MFS] [CBS], TAS [Tas Smoke Alarms Regs 2022], ACT [ACT RTA 1997] [ACT RT Regulation 1998], NT [NT Fire and Emergency Regs]. Full detail is on each state page.

Queensland landlords: what exactly do I have to do?

Since 1 January 2022, every new lease and renewal has triggered the full Queensland standard [Fire Services Act 1990 (Qld)]. The RTA says all rental "domestic dwellings" must have interconnected photoelectric alarms, including houses, townhouses, units, apartments and secondary dwellings such as granny flats [RTA].

  • Within 30 days before a tenancy starts, including the start of a renewed tenancy, test each alarm, replace spent or nearly spent batteries, and clean each alarm [Fire Services Act 1990 (Qld)] [RTA].
  • You can't ask the tenant to do the start-of-tenancy test for you [RTA].
  • Give 48 hours' entry notice to install, maintain, test or replace alarms [RTA].
  • A non-working alarm may count as an emergency repair [RTA].
  • Replace alarms within 10 years of manufacture, and immediately if one fails a test [Fire Services Act 1990 (Qld)].

NSW landlords

NSW Fair Trading lists the duties: check alarms every year, install or replace removable batteries every year (lithium per the maker), repair or replace a faulty alarm within 2 business days, replace alarms within 10 years of manufacture, and use a licensed electrician for hardwired alarms [NSW Fair Trading]. You must give at least 2 business days' notice to inspect, and 1 hour's notice to do the repair [NSW Fair Trading]. You "cannot delegate responsibility of working smoke alarms to tenants" [NSW Fair Trading].

Victorian rental providers

From 25 November 2025, every rental must have a smoke alarm safety check at least every 12 months [CAV changes]. The rental provider must also make sure alarms are correctly installed and working and have batteries, and must give the renter written information on how each alarm works and how to test it at or before the start of the lease [CAV]. Testing, repair or replacement of a mains alarm must be done by a suitably qualified person [Vic RTA s 68AA].

WA landlords

Before renting, and throughout the tenancy, alarms must be in working order, permanently connected to mains power (with limited 10-year battery exceptions), and under 10 years old or within their expiry date [WA Building and Energy]. Fines run up to $5,000, with $1,000 infringement notices [WA Consumer Protection]. The tenant only changes a 9 volt battery where the alarm is easily accessible [WA Consumer Protection].

SA, Tasmania, ACT and NT landlords

  • SA: the owner is responsible for installing and maintaining alarms [MFS]. A lease clause making the tenant test alarms and replace batteries is not enforceable [CBS].
  • Tasmania: test on the first day of each tenancy; replace faulty alarms as soon as practicable and all alarms before expiry; maximum fine for not installing compliant alarms is 50 penalty units [Tas Smoke Alarms Regs 2022] [Tas Residential Tenancy Act].
  • ACT: you must not sign a lease unless compliant alarms are installed [ACT RTA 1997].
  • NT: within 30 days before a tenancy, test, clean and replace failed alarms and spent standby batteries, and give the tenant written information about testing and maintenance. Older ionisation alarms must be replaced with photoelectric before a new, renewed or extended lease takes effect [NT Fire and Emergency Regs].

What records should a landlord keep?

No state I checked prescribes a format, but keep: the date and result of every test, battery changes, each alarm's manufacture date and position, invoices for installation, and the written information given to tenants where required (Victoria and the NT) [CAV] [NT Fire and Emergency Regs]. If anything goes wrong, those records show you met your duties.

Tenant side: smoke alarms for tenants.

Sources

Every source below was read on the official page. Last checked: November 2026.

  1. Queensland Legislation: Fire Services Act 1990, Part 9A, ss 147W to 148K (PDF, current as at 6 December 2025)
  2. Residential Tenancies Authority (Qld): Smoke alarms
  3. NSW Government (NSW Fair Trading): Smoke alarms in a rental property
  4. Consumer Affairs Victoria: Smoke alarms and fire safety (renting)
  5. Consumer Affairs Victoria: New changes to rental laws
  6. Victorian Legislation: Residential Tenancies Act 1997 (Vic), authorised version 111, section 68AA (PDF)
  7. Building and Energy, Government of Western Australia: Smoke alarm laws for homes being sold, rented and hired
  8. Consumer Protection WA: Rental home safety
  9. SA Metropolitan Fire Service: Smoke alarms fact sheet
  10. Consumer and Business Services SA: Rental agreement terms inconsistent with the Residential Tenancies Act 1995 (PDF, July 2024)
  11. Tasmanian Legislation: Residential Tenancy (Smoke Alarms) Regulations 2022 (Tas)
  12. Tasmanian Legislation: Residential Tenancy Act 1997 (Tas), Part 3A Smoke alarms
  13. ACT Legislation Register: Residential Tenancies Act 1997 (ACT), s 11B and standard terms 53A and 63A (PDF)
  14. ACT Legislation Register: Residential Tenancies Regulation 1998 (ACT), s 1B (PDF)
  15. NT Legislation: Fire and Emergency Regulations 1996 (NT), Part 2A (reprint as in force at 16 July 2024, PDF)
  16. Fallon Solutions (one company's advertised price): Smoke alarms