Interconnected smoke alarm models compared
Fourteen wireless and 240V models compared on network size, power, standard and warranty.
General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.
Short answer
Most interconnected smoke alarms sold in Australia are photoelectric and state AS 3786. The real differences are how many alarms each system links (from 12 to 40), whether it is wireless battery, 240 volt, or both, and the warranty (3 to 10 years). This table lists 14 models using each maker's own published specifications. I have not tested any of them and none has paid to be here.
Pick a system first, then a model. Once you choose a brand and range, every alarm in the house should come from it, because alarms from different makers don't interconnect [CFA types]. The tables below tell you what each range can do. For what each costs, see prices.
Wireless 10-year lithium interconnected models
| Model | Links up to | Standard stated | Warranty stated | Notes |
|---|---|---|---|---|
| Brooks EIB650iRF [Brooks EIB650iRF] | 12 devices | AS 3786 (page cites both 2014 and 2023) | 5 years (limited) | RadioLINK+ wireless |
| Red R10RF [Red R10RF] | 20 Red alarms (Red's page) | AS 3786:2014 | 10 years | Links with Red 240 V alarms fitted with Red's RF base |
| FirePro Connect [Bunnings FirePro 6 pack] | 22 | AS 3786:2014 | 3 years | Bunnings brand, 433 MHz, 25 m stated range; not compatible with FP520V |
| PSA Lifesaver LIF6000DCW [PSA LIF6000DCW datasheet] | 24 | AS 3786:2014 | 10 years | Optional Test, Hush and Locate remote |
| Quell Q5000 [Quell Q5000] | 32 | AS 3786:2014 | 10 years | Separate bedroom and living/hallway versions; 100 m line of sight |
| Clipsal 755LPSMA4 [Clipsal 755LPSMA4 datasheet] | 40 | AS 3786:2014 | 5 years | Links with Clipsal 755 mains alarms fitted with the 755RFB2 base |
| Cavius 2107 CAV10WF [Cavius 2107] | Not stated | AS 3786:2014 | 10 years | "Wireless Family" range |
240 volt interconnectable models
| Model | Backup | Interconnect | Links up to | Warranty stated |
|---|---|---|---|---|
| Clipsal 755PSMA5 [Sparky Direct 755PSMA5] | 9 V alkaline | Wired; wireless with 755RFB2 base | 40 | 5 years |
| Red R240 [Red R240] | 9 V | Wired; wireless with Red RF base | 40 Red alarms | 10 years |
| Brooks EIB3016 [Brooks EIB3016] | Rechargeable 10-year lithium, non-removable | Wired; wireless with EIB3000MRF module | 12 devices | 5 years (limited) |
| FirePro 240V Connect [Bunnings FirePro 240V] | 10-year sealed lithium | Wired and wireless | 22 wireless or 30 wired | 3 years |
| PSA Lifesaver LIF6800 / LIF6800RL [PSA brochure] | 9 V (6800) or 10-year rechargeable lithium (6800RL) | Wired; wireless with 6000WB base | 24 smoke and heat alarms | Not checked |
| Cavius 2203 CAVMP [Cavius 2203] | Not stated on the AU page | Wireless Family RF | Not stated | 10 years |
| Red RSDUALP [Red RSDUALP] | Runs on 240 V or a sealed 10-year lithium battery (sensor type not stated on the page) | Hardwired or RF module | Not stated | 10 years |
How do these ranges show which alarm went off?
- Red: the triggered alarm's red light flashes every 5 seconds for 72 hours [Red R10RF].
- Brooks EIB3016: for 24 hours after alarming, the red LED flashes twice every 48 seconds, and memory can be recalled by pressing and holding test [Brooks manuals].
- PSA LIF6000DCW: "only the red LED of initiating unit will flash" [PSA LIF6000DCW datasheet].
- Clipsal 755PSMA4: the triggered alarm flashes its red LED once every 2 seconds for 72 hours [Clipsal manual].
Which brand should I choose?
I can't honestly name a winner without testing, and I haven't. These questions narrow it down:
- Do you have hardwired alarms now? Choose a brand whose 240 volt alarm takes a wireless base and whose battery alarm links to it (Clipsal, Red, Brooks, PSA, FirePro all describe this).
- Fitting it yourself? Pick a wireless 10-year range that is easy to buy more of later, so you can add or replace alarms.
- Big house or granny flat? Check the network maximum and stated range.
- Older occupants or high ceilings? Look for a range with a wall controller or remote.
- In Queensland? Photoelectric only, no ionisation sensor, AS 3786-2014 [Building Fire Safety Regulation 2008 (Qld)].
More detail in what to look for, and where to buy them in where to buy.
Sources
Every source below was read on the official page. Last checked: November 2026.
- Country Fire Authority (Victoria): Types of smoke alarms
- Brooks Australia: EIB650iRF 10 year lithium photoelectric smoke alarm with RadioLINK
- Red Smoke Alarms: Smoke alarm 10 year RF wireless (R10RF)
- Bunnings Warehouse: FirePro Connect 10 year lithium wireless interconnect smoke alarm, 6 pack ($229.00 seen 3 Nov 2026, VIC Metro pricing)
- PSA Products (Lifesaver): Lifesaver LIF6000DCW datasheet V2.00 (PDF, hosted by Sparky Direct)
- Quell (Kidde Australia): Q5000 wireless interconnect photoelectric smoke alarm
- Clipsal by Schneider Electric: 755LPSMA4 wireless 10 year lithium smoke alarm datasheet (PDF, hosted by Sparky Direct)
- Cavius Australia: 2107 CAV10WF Wireless Family smoke alarm
- Sparky Direct: Clipsal 755PSMA5 230V smoke alarm surface mount ($40.59 inc GST seen 3 Nov 2026)
- Red Smoke Alarms: Smoke alarm 240V with 9V battery back up (R240)
- Brooks Australia: EIB3016 photoelectric 230 V smoke alarm with 10 year lithium battery backup
- Bunnings Warehouse: FirePro 240V Connect wireless interconnect smoke alarm ($52.00 seen 3 Nov 2026, VIC Metro pricing)
- PSA Products (Lifesaver): Lifesaver 6000 series brochure (PDF, hosted by Sparky Direct)
- Cavius Australia: 2203 CAVMP mains powered smoke alarm
- Red Smoke Alarms: Smoke alarm 240V or 10 year lithium dual power (RSDUALP)
- Clipsal by Schneider Electric: 755PSMA4 240 V smoke alarm datasheet (PDF, hosted by Sparky Direct)
- Brooks Australia: Data sheets and manuals (EIB3016 owner's manual)
- Clipsal by Schneider Electric: 755PSMA4 photoelectric smoke alarm instruction sheet (PDF, copy hosted by Sparky Direct) (manufacturer instructions for one 240 V model)
- Queensland Legislation: Building Fire Safety Regulation 2008, Part 5A, ss 55C to 55E (PDF)