Buying

What to look for when buying interconnected smoke alarms

Ten things to check before you buy, including the Queensland dual-sensor trap.

General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.

Short answer

Buy photoelectric alarms marked with AS 3786, all from one brand and one range so they interconnect. Choose a sealed 10-year lithium wireless alarm if you are fitting them yourself, or 240 volt with a backup battery if an electrician is wiring them. Check the maximum number of alarms the system links, the manufacture date, and that it has hush and a "which alarm started it" feature. In Queensland, avoid dual-sensor alarms.

This is a checklist for the shop or the website. Work down it and you will avoid the mistakes that cost people a second trip: alarms that won't link with each other, alarms that are already two years into their ten, and alarms that don't meet the rules in their state.

1. Is it photoelectric?

Queensland requires a photoelectric sensor and no ionisation sensor [Building Fire Safety Regulation 2008 (Qld)], and the NT's approved alarms are photoelectric [NT Fire and Emergency Regs]. Most other fire services recommend photoelectric too. The type is printed on the box and the label. See photoelectric vs ionisation.

2. Does it carry AS 3786?

Every state requires AS 3786. The current edition is AS 3786:2023 [AS 3786:2023]. Queensland's regulation names AS 3786-2014 [Building Fire Safety Regulation 2008 (Qld)], and the Queensland Government says the standard is "marked on the body of the alarm" [qld.gov.au]. Most interconnected alarms I found state AS 3786:2014 [Red R10RF] [Quell Q5000] [Cavius 2107]. If you are in Queensland and an alarm only shows the 2023 edition, ask the maker or QFD whether it meets the Queensland rule.

3. Wireless battery or 240 volt?

  • Wireless with a sealed 10-year lithium battery if no alarms in the home are hardwired and you want to fit them yourself.
  • 240 volt with backup if you are replacing existing hardwired alarms (required in Queensland and the ACT [Fire Services Act 1990 (Qld)] [ACT ESA]), building, or selling or renting in WA [WA Building and Energy].

If you go 240 volt, consider a model with a 10-year lithium backup rather than a 9 volt, so there is no yearly battery change. Compare in wireless vs hardwired.

Only if they are the same brand and compatible range. The CFA says all the alarms in your home "must use the same technology to connect to one another and work properly" [CFA types], and AFAC warns that "not all smoke/heat alarm brands and/or models are interconnectable or compatible" [AFAC]. Even within a brand, check the range: FirePro's Connect alarms note they are "not interconnectable with the FP520V model" [Bunnings FirePro 6 pack]. See mixing brands.

Makers set a maximum. A few I checked:

Any of these covers a normal house, but check if you have a large home or a granny flat on the same system.

6. When was it made?

The 10 years runs from manufacture, not purchase [AFAC], and Queensland requires an alarm to have been made less than 10 years before it is installed [Fire Services Act 1990 (Qld)]. Look for the date on the box or the alarm. Fire and Rescue NSW notes AS 3786 requires a serial or batch number on the device, and gives the example that "2406 may mean that the product was manufactured in the 24th week of 2006" [FRNSW FAQ].

7. Does it have hush and alarm memory?

Hush silences a nuisance alarm for a short time. Brooks, Red, Clipsal and PSA all describe about 10 minutes [Brooks FAQ] [Red R10RF manual] [Clipsal 755LPSMA4 datasheet] [PSA LIF6000DCW datasheet]. Alarm memory shows which alarm detected the smoke after the whole house went off. On Red alarms the triggered unit flashes every 5 seconds for 72 hours [Red R10RF], and on PSA's LIF6000DCW only the initiating unit's red LED flashes [PSA LIF6000DCW datasheet]. That saves a lot of ladder climbing at 3am.

8. Is there a wall controller or remote?

Some ranges offer a wall switch or remote that tests, hushes and locates alarms without a ladder, for example PSA's LIF6000THL "Test, Hush, and Locate" controller [PSA brochure]. Useful for high ceilings and older people. Controllers only work with their own brand: Red says its controllers "only work with Red Smoke Alarms" [Red FAQ].

9. Bedroom or living room version?

A few ranges sell slightly different models for different rooms. Quell, for example, sells the Q5000 in a living or hallway version and a bedroom version [Quell Q5000]. Read the box to make sure you have the right mix.

10. Warranty

Warranties I saw range from 3 years (FirePro) to 5 years (Clipsal, Brooks) to 10 years (Red, Quell, PSA, Cavius) [Bunnings FirePro 6 pack] [Clipsal 755LPSMA4 datasheet] [Brooks EIB650iRF] [Red R10RF] [Quell Q5000] [PSA LIF6000DCW datasheet] [Cavius 2107]. These are the makers' own statements.

What to avoid

  • Wi-Fi-only "smart" linking. AFAC says Wi-Fi interconnection should not be used [AFAC].
  • Carbon monoxide alarms sold as if they were smoke alarms. Fire and Rescue NSW says CO alarms "are not smoke alarms and do not satisfy the legislation" [FRNSW FAQ].
  • Unbranded marketplace sets with no AS 3786 marking.
  • Mixing two brands because one was on special.

Next: models compared and current prices.

Sources

Every source below was read on the official page. Last checked: November 2026.

  1. Queensland Legislation: Building Fire Safety Regulation 2008, Part 5A, ss 55C to 55E (PDF)
  2. NT Legislation: Fire and Emergency Regulations 1996 (NT), Part 2A (reprint as in force at 16 July 2024, PDF)
  3. Country Fire Authority (Victoria): Types of smoke alarms
  4. Standards Australia: AS 3786:2023 Smoke alarms using scattered light, transmitted light or ionization (store page)
  5. Queensland Government (qld.gov.au): Smoke alarms (page last updated 29 October 2026)
  6. Red Smoke Alarms: Smoke alarm 10 year RF wireless (R10RF)
  7. Quell (Kidde Australia): Q5000 wireless interconnect photoelectric smoke alarm
  8. Cavius Australia: 2107 CAV10WF Wireless Family smoke alarm
  9. Queensland Legislation: Fire Services Act 1990, Part 9A, ss 147W to 148K (PDF, current as at 6 December 2025)
  10. ACT Emergency Services Agency (ACT Fire & Rescue): Smoke alarms
  11. Building and Energy, Government of Western Australia: Smoke alarm laws for homes being sold, rented and hired
  12. AFAC (National Council for fire and emergency services): Smoke alarms in domestic and residential accommodation, guideline v4.0 (October 2023)
  13. Bunnings Warehouse: FirePro Connect 10 year lithium wireless interconnect smoke alarm, 6 pack ($229.00 seen 3 Nov 2026, VIC Metro pricing)
  14. Brooks Australia: EIB650iRF 10 year lithium photoelectric smoke alarm with RadioLINK
  15. PSA Products (Lifesaver): Lifesaver LIF6000DCW datasheet V2.00 (PDF, hosted by Sparky Direct)
  16. Clipsal by Schneider Electric: 755LPSMA4 wireless 10 year lithium smoke alarm datasheet (PDF, hosted by Sparky Direct)
  17. Fire and Rescue NSW: Smoke alarm questions and answers
  18. Brooks Australia: Frequently asked questions
  19. Red Smoke Alarms: R10RF instruction manual (PDF)
  20. PSA Products (Lifesaver): Lifesaver 6000 series brochure (PDF, hosted by Sparky Direct)
  21. Red Smoke Alarms: Red Smoke Alarms home page FAQ