Interconnected smoke alarm wiring explained (and why it is an electrician's job)
Active, neutral and interconnect explained with a concept diagram, plus what to ask your electrician.
General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.
Short answer
A hardwired interconnected smoke alarm system runs three conductors to each alarm base: an active, a neutral and an interconnect wire. When one alarm detects smoke it signals down the interconnect wire and every other alarm on the link sounds. Wiring them is electrical work on a 240 volt circuit, so in Australia it must be done by a licensed electrician. If you want to do it yourself, the legal route is a wireless battery-powered interconnected system instead.
People search for an interconnected smoke alarm wiring diagram for two reasons. Some want to understand what the electrician is quoting for. Others are hoping to wire them up on the weekend. This page is for the first group. It explains how the wiring works in principle, using one manufacturer's published instructions as the worked example, so you can follow a quote and ask sensible questions. It is not an installation guide.
What does an interconnected smoke alarm wiring diagram show?
A typical diagram shows a row of smoke alarm bases, each with a small terminal block. On the Clipsal 755 series the terminals are marked A (active), N (neutral), E-Loop (earth or loop) and I-Connect (interconnect)[Clipsal manual]. The active and neutral bring power to each alarm. The interconnect terminal on every base is joined to the interconnect terminal on every other base by its own conductor.
When any alarm senses smoke, it puts a signal on the interconnect conductor. The other alarms see that signal and sound too. That is the whole trick behind "one goes off, they all go off".
What rules do the manufacturer instructions set?
These come from the published instruction sheet for the Clipsal 755PSMA4, a 240 volt photoelectric alarm with a 9 volt backup battery [Clipsal manual]. Other brands have their own rules, which is exactly why an electrician works from the instructions for the model being installed.
- All interconnected smoke alarms must be supplied from the same circuit.
- A common neutral must be used for the interconnect to work.
- The interconnect wire must not be connected to active or neutral.
- A maximum of 40 alarms can be interconnected.
- The maximum wire length between the first and last alarm is 150 metres.
- Cable of at least 1 mm² is used for all wiring, including the interconnect.
- Only Clipsal alarms are compatible for interconnection with that alarm.
- If running an interconnect cable is not possible, the maker sells an optional wireless base (catalogue number 755RFB2) that links up to 40 alarms without the interconnect wire.
That last point matters for older homes. If an electrician can't get a new cable between two rooms without pulling the ceiling apart, many 240 volt alarms can be fitted with a wireless base or module so the mains alarms still talk to each other. Read more in wireless vs hardwired interconnected smoke alarms.
Why can't I just copy the old wiring?
Many older hardwired alarms were installed as standalone units with only an active and neutral. To interconnect them, the electrician needs either a third conductor between the bases or a wireless interconnect module on each one. Swapping a new alarm onto an old two-wire base will give you a powered alarm that is not linked to anything. In Queensland, that would not meet the interconnection rule that applies to all homes from 1 January 2027. See the Queensland 2027 deadline.
Can I mix brands on the same interconnect wire?
Usually not. The Clipsal instructions above say only Clipsal alarms are compatible for interconnection with that model [Clipsal manual], and other makers publish similar warnings. Different brands use different signals on the interconnect line and different wireless protocols. If you are replacing one alarm in an existing system, match the brand and series, or replace the whole set. More in can you mix smoke alarm brands.
What does the electrician do after wiring?
The same instructions tell the installer to test each interconnected unit one at a time and check that every other alarm sounds during each test [Clipsal manual]. If any alarm fails to sound, the wiring and connections are checked. Ask your electrician to walk you through that test before they leave, and test again yourself afterwards. My testing guide covers how.
What questions should I ask the electrician?
- Will all the alarms be on the same circuit, as the maker requires?
- Are you running interconnect cable, or using wireless modules where cable can't go?
- Are the alarms photoelectric and do they meet the rules for my state?
- Where will each alarm go, and does that meet the location rules for bedrooms, hallways and each storey?
- Will you test every alarm and show me that they all sound together?
- Will I get a certificate of testing or compliance paperwork for the electrical work?
For typical prices, see smoke alarm installation cost.
Sources
Every source below was read on the official page. Last checked: November 2026.
- Electrical Safety Office Queensland: Don't do your own electrical work
- Clipsal by Schneider Electric: 755PSMA4 photoelectric smoke alarm instruction sheet (PDF, copy hosted by Sparky Direct) (manufacturer instructions for one 240 V model)