Where to put smoke alarms, and how many you need
Legal minimum locations by state, recommended spots, worked counts and the placement distances.
General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.
Short answer
The legal minimum in most of Australia is a smoke alarm in the hallway outside the bedrooms and one on every storey. Queensland also requires one in every bedroom. Fire services recommend an alarm in every bedroom and living area, all interconnected. Put alarms on the ceiling, at least 300mm from walls and lights, and away from kitchens, bathrooms and air conditioner vents.
Where are smoke alarms legally required?
| State | Minimum locations |
|---|---|
| Queensland | Every bedroom; hallway serving bedrooms (or between bedrooms and the rest); every storey on the path to an exit |
| NSW | Every level; hallways near bedrooms (each bedroom area if they are apart) |
| Victoria | Every storey; between each bedroom area and the rest of the house |
| WA (sale, rental, hire) | Every corridor serving a bedroom (or between bedrooms and the rest); every storey |
| SA | Locations that give reasonable warning to people in bedrooms |
| Tasmania (rentals) | Every corridor serving a bedroom (or between); every other storey |
| ACT (rentals) | Every corridor serving a bedroom (or between); every storey |
| NT | Building Code locations (hallways to bedrooms, every storey) |
Sources: Queensland [Building Fire Safety Regulation 2008 (Qld)], NSW [FRNSW law], Victoria [BPC], WA [WA Building and Energy], SA [SA PDI Regs r 95], Tasmania [Tas Smoke Alarms Regs 2022], ACT [ACT RT Regulation 1998], NT [NT Fire and Emergency Regs] and the NCC [NCC 2025 Part 9.5].
Where do fire services recommend putting smoke alarms?
Further than the law. AFAC, the national fire services council, says interconnected alarms "should be installed in all sleeping areas, living spaces, paths of travel (hallways, stairways) and garages if they are under the home's main roof" [AFAC]. State fire services say much the same: FRV and the CFA say every bedroom and living area [FRV], Fire and Rescue NSW says all bedrooms and living spaces including hallways and stairways and even the garage [FRNSW buyers guide], and DFES lists every bedroom, living room, hallway, stairway and garage [DFES].
Why put a smoke alarm inside the bedroom?
Because doors block sound and smoke. FRV says "when a fire starts in a bedroom with doors closed, the smoke alarm outside the bedroom will not activate" [FRV]. A national building code study found that with doors closed, the sound at the bedhead in other rooms averaged 36 dBA, well under the roughly 75 dBA typically needed to wake a sleeper [ABCB RIS 2013]. AFAC notes more fatal fires happen between 10pm and 6am, and more than half of fatal home fires begin in bedrooms and living or lounge rooms [AFAC].
How many smoke alarms do I need?
Count your bedrooms, hallways and storeys. As a guide:
| Home | Queensland minimum | Typical minimum elsewhere | Fire service recommendation |
|---|---|---|---|
| 1 storey, 3 bedrooms, 1 hallway, open living | 4 | 1 | 5 (adds the living area) |
| 1 storey, 4 bedrooms in two wings | 6 (4 bedrooms, 2 hallways) | 2 | 7 or more |
| 2 storeys, 4 bedrooms upstairs, living downstairs | 6 (4 bedrooms, upstairs hall, downstairs exit path) | 2 | 7 or more (adds stairway, living) |
These are my worked examples using the location rules above. Your floor plan may differ, especially in WA and SA where the trigger and wording differ. In Queensland, every one of those alarms must also be interconnected [Fire Services Act 1990 (Qld)].
Ceiling or wall?
Ceiling, where you can. The NCC says alarms go on the ceiling at least 300mm from the corner where wall meets ceiling. If that's not possible, on the wall 300mm to 500mm below the ceiling [NCC 2025 Part 9.5]. Queensland's regulation instead allows the wall 100mm to 300mm below the ceiling and more than 300mm from a corner [Building Fire Safety Regulation 2008 (Qld)]. FRV suggests the ceiling "close to the centre of the room, and at least 30cm away from the wall" [FRV brochure].
The reason is dead air. Hot air gets trapped in corners and at the apex of a raked ceiling, and can stop smoke reaching the alarm [NCC 2025 Part 9.5]. On a sloping ceiling, place the alarm 500mm to 1,500mm from the apex [NCC 2025 Part 9.5].
How far from lights, fans and air conditioners?
Queensland writes this into law, and DFES in WA recommends the same distances [Building Fire Safety Regulation 2008 (Qld)] [DFES]:
- At least 300mm from a light fitting.
- At least 300mm from the corner of a ceiling and wall.
- At least 400mm from an air conditioning vent, heating or cooling duct.
- At least 400mm from ceiling fan blades.
Moving air from a vent or fan can blow smoke away from the alarm, or blow dust into it. See the Queensland placement diagram.
Where should smoke alarms not go?
- Kitchens. Cooking fumes cause false alarms. The CFA says alarms are not needed in kitchens, laundries or bathrooms [CFA installation], and Fire and Rescue NSW says to avoid fitting them in or near the kitchen or bathroom [FRNSW installation].
- Bathrooms and laundries. Steam sets them off [DFES].
- Garages, for smoke alarms. One maker's instructions say a heat alarm is more suitable in a garage because it isn't affected by particles [Clipsal manual]. The NCC allows a different alarm type in a garage where smoke alarms would cause false alarms [NCC 2025 Part 9.5].
- Dead air spaces in corners and at the very top of raked ceilings [NCC 2025 Part 9.5].
What about stairs and split levels?
Smoke rises up a stairwell, so the top of the stairs is a natural spot. Queensland's regulation says an alarm in a stairwell must not be where an obstruction stops rising smoke reaching it [Building Fire Safety Regulation 2008 (Qld)]. The NT Government suggests an additional alarm in the stairway between each level of a multilevel home [nt.gov.au], and Tasmania Fire Service recommends the top of stairs [TFS].
Next: choose wireless or hardwired, or see how to upgrade an existing home.
Sources
Every source below was read on the official page. Last checked: November 2026.
- Queensland Legislation: Building Fire Safety Regulation 2008, Part 5A, ss 55C to 55E (PDF)
- Queensland Legislation: Fire Services Act 1990, Part 9A, ss 147W to 148K (PDF, current as at 6 December 2025)
- Fire and Rescue NSW: Smoke alarms: what is the law?
- Building and Plumbing Commission (Victoria): Smoke alarms (safety guide)
- Building and Energy, Government of Western Australia: Smoke alarm laws for homes being sold, rented and hired
- South Australian Legislation: Planning, Development and Infrastructure (General) Regulations 2017, regulation 95 (PDF)
- Tasmanian Legislation: Residential Tenancy (Smoke Alarms) Regulations 2022 (Tas)
- ACT Legislation Register: Residential Tenancies Regulation 1998 (ACT), s 1B (PDF)
- NT Legislation: Fire and Emergency Regulations 1996 (NT), Part 2A (reprint as in force at 16 July 2024, PDF)
- Australian Building Codes Board: NCC 2025 Housing Provisions Part 9.5 Smoke alarms and evacuation lighting
- AFAC (National Council for fire and emergency services): Smoke alarms in domestic and residential accommodation, guideline v4.0 (October 2023)
- Fire Rescue Victoria: Smoke alarms (page updated 9 September 2026)
- Fire Rescue Victoria: Smoke alarms brochure (PDF)
- Fire and Rescue NSW: Smoke alarm buyers guide
- Department of Fire and Emergency Services WA: Smoke alarms
- Australian Building Codes Board: Regulation Impact Statement: Interconnection of Smoke Alarms (October 2013, PDF)
- Country Fire Authority (Victoria): Smoke alarm installation
- Fire and Rescue NSW: Smoke alarm installation guide
- Clipsal by Schneider Electric: 755PSMA4 photoelectric smoke alarm instruction sheet (PDF, copy hosted by Sparky Direct) (manufacturer instructions for one 240 V model)
- Tasmanian Legislation: Residential Tenancy Act 1997 (Tas), Part 3A Smoke alarms
- Northern Territory Government (nt.gov.au): Smoke alarms
- Tasmania Fire Service: Smoke alarms (home fire safety)