Interconnected smoke alarms explained
What interconnected means, how wired and wireless links work, and where they are required by law.
General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.
Short answer
Interconnected smoke alarms are linked so that when one detects smoke, they all sound. The link can be a wire in the ceiling or a wireless radio signal. Queensland's law defines it exactly that way: each alarm sounds if the other detects smoke. The point is to wake everyone, wherever the fire starts, especially people asleep behind closed doors.
What does interconnected mean for smoke alarms?
It means the alarms talk to each other. Queensland's Fire Services Act gives the clearest legal definition: an alarm is interconnected to another if it "sounds an alert if the other smoke alarm is activated because its sensor detects smoke", and the other way around [Fire Services Act 1990 (Qld)]. The law describes the result, not the method.
Fire and Rescue NSW explains the method: "The interconnection of multiple alarms ensures that if one alarm detects smoke, all alarms will activate to sound the warning. Alarms can be interconnected by wires in the ceiling space or by wireless interconnection" [FRNSW research].
Why do interconnected smoke alarms matter?
Because an alarm you can't hear is no use. Fire Rescue Victoria puts it bluntly: "when a fire starts in a bedroom with doors closed, the smoke alarm outside the bedroom will not activate" [FRV]. The reverse also happens. A fire in the living room at 2am sets off the living room alarm, but people asleep in bedrooms with the doors shut may not hear it in time.
The Queensland Fire Department says "interconnected smoke alarms give you more time to escape. When one smoke alarm sounds, they all sound. This alerts everyone in the home if there is a fire" [QFD fact sheet]. Fire and Rescue NSW goes further: the critical factor in how well smoke alarms work "is not a specific sensor technology but rather the number of alarms used, their location and the interconnection between units" [FRNSW research].
How do interconnected smoke alarms work?
There are two ways to link them:
Hardwired interconnection
The alarms are wired into the 240 volt supply, and an extra conductor runs between them. When one alarm senses smoke it sends a signal down that wire and the others sound. One maker's instructions, for example, allow up to 40 alarms on one interconnect line, all supplied from the same circuit [Clipsal manual]. This has to be installed by a licensed electrician. See interconnected smoke alarm wiring explained.
Wireless interconnection
Each alarm has a small radio built in. When one alarm senses smoke, it broadcasts a signal and the others sound. Wireless alarms are usually powered by a sealed 10-year lithium battery, so no wiring is needed at all. The Queensland Fire Department says wireless alarms "connect without wiring, and can be installed yourself" [QFD fact sheet]. Many 240 volt alarms can also take a wireless module, so hardwired and battery alarms can be linked, if the maker supports it. Compare the two in wireless vs hardwired.
Where are interconnected smoke alarms required by law?
| State | Interconnection required |
|---|---|
| Queensland | All homes from 1 January 2027 (new, renovated, sold and leased homes already) |
| Victoria | Homes built, largely renovated or extended after 1 May 2014 |
| NSW | New homes with more than one alarm. Not required for existing homes |
| WA | Where more than one alarm, unless the building permit was applied for before 1 May 2015 (checked at sale, rental and hire) |
| SA | New homes and additions approved from 1 May 2014 |
| ACT | No law found for existing homes. Fire & Rescue recommends it |
Sources: Queensland [qld.gov.au], Victoria [FRV], NSW [NCC 2025 NSW 9.5], WA [WA Building and Energy], SA [MFS legislation], ACT [ACT ESA]. Tasmania and the Northern Territory are covered on their own pages. For every state in one table, see the laws by state hub.
Do all the alarms have to be the same brand?
In practice, yes. The CFA says: "All the smoke alarms in your home must use the same technology to connect to one another and work properly" [CFA types]. Wireless systems use each maker's own radio protocol, and wired interconnect signals differ between brands. One maker's instructions state that only its own alarms are compatible for interconnection [Clipsal manual]. See can you mix smoke alarm brands.
If one alarm goes off, how do I know which one detected the smoke?
Most interconnected alarms have a memory or locate feature. On one common model, the alarm that triggered keeps flashing its red light once every 2 seconds for 72 hours after the noise stops, so you can identify it [Clipsal manual]. Other brands do this differently, so check your manual. This matters for false alarms: if the whole house goes off at 3am, you need to find the one that started it. See why smoke alarms keep going off.
How do I test interconnected smoke alarms?
Press the test button on one alarm and check every other alarm sounds. Then repeat from each alarm in turn. The SA Metropolitan Fire Service says to "ensure all interconnected smoke alarms activate at the same time when any one of the test buttons is pressed" [MFS]. Fire services recommend testing monthly. Full routine in testing and cleaning.
Are interconnected smoke alarms worth it if my state doesn't require them?
Every fire service I checked recommends them, including in states where they are not compulsory for existing homes. FRV's "best" option is a wireless interconnected alarm with a 10-year lithium battery [FRV]. Fire and Rescue NSW recommends hardwired and interconnected alarms wherever possible [FRNSW buyers guide]. DFES in WA and the SA MFS recommend them too [DFES] [MFS]. Wireless sets have made them a weekend job rather than a renovation. See what they cost.
Sources
Every source below was read on the official page. Last checked: November 2026.
- Queensland Legislation: Fire Services Act 1990, Part 9A, ss 147W to 148K (PDF, current as at 6 December 2025)
- Fire and Rescue NSW: Smoke alarms in homes (projects and research)
- Fire Rescue Victoria: Smoke alarms (page updated 9 September 2026)
- Queensland Fire Department: Smoke alarm laws are changing in Queensland (fact sheet QFE00206, PDF)
- Clipsal by Schneider Electric: 755PSMA4 photoelectric smoke alarm instruction sheet (PDF, copy hosted by Sparky Direct) (manufacturer instructions for one 240 V model)
- Queensland Government (qld.gov.au): Smoke alarms (page last updated 29 October 2026)
- Australian Building Codes Board: NCC 2025 Housing Provisions, Schedule 5 New South Wales, NSW Part 9.5 Smoke alarms
- Building and Energy, Government of Western Australia: Smoke alarm laws for homes being sold, rented and hired
- SA Metropolitan Fire Service: Smoke alarm legislation fact sheet
- ACT Emergency Services Agency (ACT Fire & Rescue): Smoke alarms
- Country Fire Authority (Victoria): Types of smoke alarms
- SA Metropolitan Fire Service: Smoke alarms fact sheet
- Fire and Rescue NSW: Smoke alarm buyers guide
- Department of Fire and Emergency Services WA: Smoke alarms