How to upgrade an existing home to interconnected smoke alarms
Four common starting points, which need an electrician, and how to mix hardwired and wireless.
General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.
Short answer
To upgrade an existing home to interconnected smoke alarms, first record what you have: how many alarms, where, their type, power and age. If none are hardwired, replace them all with one brand of wireless 10-year lithium photoelectric alarms. If some are hardwired, get an electrician to replace those with same-brand 240 volt alarms that take a wireless base, then add matching battery alarms in the other rooms. Test every alarm sets off all the others.
This is the job most Queensland owner-occupiers face before 1 January 2027, and the one fire services in every other state recommend [qld.gov.au] [FRNSW buyers guide] [FRV]. Most homes fall into one of four starting points. Find yours below.
Step 1: what do I have now?
For each alarm, note:
- Room and position.
- Photoelectric or ionisation. Ionisation alarms carry a radiation symbol [MFS disposal].
- Power: hardwired (wired into the ceiling), removable 9 volt battery, or sealed 10-year lithium.
- Manufacture date. Replace anything over 10 years old [AFAC].
- Brand and model.
Then press test on one alarm. If the others don't sound, the system isn't interconnected.
Step 2: which starting point am I?
| What you have now | Usual upgrade | Electrician? |
|---|---|---|
| A. Only battery alarms (9 V or sealed), none hardwired | Replace all with one brand of wireless 10-year lithium photoelectric alarms; add bedroom alarms | No (check WA and Tas rental rules) |
| B. One or two hardwired alarms in the hallway | Electrician replaces hardwired units with 240 V alarms plus wireless bases; you add same-brand battery alarms in bedrooms | Yes, for the hardwired positions |
| C. Several hardwired alarms already wired together | Electrician replaces like for like with photoelectric 240 V alarms on the existing interconnect; add bedrooms by wire or wireless base | Yes |
| D. Hardwired, but under 10 years old, photoelectric and interconnected | Add alarms where missing (often bedrooms) from the same brand and range | Depends on the brand's options |
In Queensland and the ACT, a hardwired alarm must be replaced with a hardwired alarm [Fire Services Act 1990 (Qld)] [ACT ESA], which is why starting points B and C need an electrician. In WA, homes being sold, rented or hired generally need mains-powered alarms [WA Building and Energy].
Step 3: how many alarms, and where?
In Queensland: every bedroom, the hallway outside the bedrooms, and every storey [Building Fire Safety Regulation 2008 (Qld)]. Elsewhere, the legal minimum is usually the hallway and each storey, but fire services recommend every bedroom and living area [AFAC]. Worked examples are on where to install.
Step 4: choose one brand that covers both power types
If you are in starting point B or C, you need a brand with a 240 volt alarm that can join a wireless network and a battery alarm that can join the same network. From the makers' own information:
- Clipsal: 755 mains alarms with the 755RFB2 base link to the 755LPSMA4 battery alarm [Clipsal 755LPSMA4 datasheet].
- Red: the R240 takes the Red RF wireless base [Red R240], and the R10RF links with Red 240 V and 10-year alarms [Red R10RF].
- Brooks: the EIB3016 mains alarm supports wireless with the EIB3000MRF module [Brooks EIB3016].
- PSA: the LIF6800 links wirelessly to the 6000 series with the 6000WB base [PSA LIF6000DCW datasheet].
- FirePro: the 240V Connect links wirelessly with the FirePro Connect series [Bunnings FirePro 240V].
Check the exact model numbers with the maker or your electrician before buying, because ranges change. See models compared.
Step 5: install, pair and test
- Electrician does the hardwired positions first, including fitting wireless bases.
- Pair your battery alarms to the system following the maker's steps.
- Mount at the right distances from walls, lights, vents and fans [Building Fire Safety Regulation 2008 (Qld)].
- Test from each alarm in turn. The SA MFS says to make sure "all interconnected smoke alarms activate at the same time when any one of the test buttons is pressed" [MFS].
What about apartments and units?
In Queensland, the rules apply to each sole-occupancy unit [Fire Services Act 1990 (Qld)]. Where a unit has a building-wide smoke detection system that meets the Building Code specification, the owner is taken to comply [Fire Services Act 1990 (Qld)]. Ask the body corporate what is installed before buying anything. In Tasmania, body corporate rules can't stop an owner installing the alarms rental law requires [Tas Residential Tenancy Act].
What about granny flats?
The Queensland RTA lists secondary dwellings such as granny flats among the rental properties that must have interconnected photoelectric alarms [RTA]. The NCC applies interconnection within each dwelling, so a separate dwelling doesn't have to link to the main house [NCC 2025 Part 9.5]. Linking them can still be sensible if people sleep in both.
Costs are on installation cost.
Sources
Every source below was read on the official page. Last checked: November 2026.
- Queensland Government (qld.gov.au): Smoke alarms (page last updated 29 October 2026)
- Fire and Rescue NSW: Smoke alarm buyers guide
- Fire Rescue Victoria: Smoke alarms (page updated 9 September 2026)
- SA Metropolitan Fire Service: Fire safety equipment disposal
- AFAC (National Council for fire and emergency services): Smoke alarms in domestic and residential accommodation, guideline v4.0 (October 2023)
- Queensland Legislation: Fire Services Act 1990, Part 9A, ss 147W to 148K (PDF, current as at 6 December 2025)
- ACT Emergency Services Agency (ACT Fire & Rescue): Smoke alarms
- Building and Energy, Government of Western Australia: Smoke alarm laws for homes being sold, rented and hired
- Queensland Legislation: Building Fire Safety Regulation 2008, Part 5A, ss 55C to 55E (PDF)
- Clipsal by Schneider Electric: 755LPSMA4 wireless 10 year lithium smoke alarm datasheet (PDF, hosted by Sparky Direct)
- Red Smoke Alarms: Smoke alarm 240V with 9V battery back up (R240)
- Red Smoke Alarms: Smoke alarm 10 year RF wireless (R10RF)
- Brooks Australia: EIB3016 photoelectric 230 V smoke alarm with 10 year lithium battery backup
- PSA Products (Lifesaver): Lifesaver LIF6000DCW datasheet V2.00 (PDF, hosted by Sparky Direct)
- Bunnings Warehouse: FirePro 240V Connect wireless interconnect smoke alarm ($52.00 seen 3 Nov 2026, VIC Metro pricing)
- SA Metropolitan Fire Service: Smoke alarms fact sheet
- Queensland Fire Department: Smoke alarm laws are changing in Queensland (fact sheet QFE00206, PDF)
- Tasmanian Legislation: Residential Tenancy Act 1997 (Tas), Part 3A Smoke alarms
- Residential Tenancies Authority (Qld): Smoke alarms
- Australian Building Codes Board: NCC 2025 Housing Provisions Part 9.5 Smoke alarms and evacuation lighting