General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.

Short answer

Every Victorian home must have smoke alarms on each storey, placed between the bedrooms and the rest of the house, and they must meet AS 3786. Homes built after 1 August 1997 need 240 volt hardwired alarms with a backup battery. Interconnection is only compulsory for homes built, largely renovated or extended after 1 May 2014, but Victoria's fire services recommend it for every home. Since 25 November 2025 rental providers must have alarms tested at least once every 12 months.

Victoria's rules depend mostly on one question: when was the house built, or last largely renovated or extended? There are three dates that matter, and the rental rules sit on top of them. This page walks through each, then covers what the fire services recommend, which in Victoria goes well past the legal minimum.

What does the law require for smoke alarms in Victoria?

The Building and Plumbing Commission (the body formerly called the Victorian Building Authority) sets out the baseline. Smoke alarms are compulsory "in every residential building, on or near the ceiling of every storey", and "they must be located between each bedroom area and the rest of the house". They must meet Australian Standard AS 3786 [BPC].

Fire Rescue Victoria puts the location rule the same way: at least one alarm on each level of every house, unit, flat and townhouse, and an alarm between each sleeping area and the rest of the house [FRV]. The legal duty sits with the owner. For older homes, regulation 145 of the Building Regulations 2018 makes it the owner of the building (or, in an apartment block, the owner of the unit) who must comply [Vic Building Regs r 145].

Which smoke alarms does my Victorian home need, by build date?

FRV publishes a minimum requirement table. In plain terms [FRV]:

Minimum smoke alarm requirement in Victoria by construction date (from FRV)
When the home was built, largely renovated or extendedMinimum required
Before 1 August 1997Stand-alone 9 volt battery-powered smoke alarms
After 1 August 1997Hardwired alarms connected to 240 volt mains power, with a backup battery
After 1 May 2014Interconnected, hardwired alarms connected to 240 volt mains power, with a backup battery

The CFA uses the same three bands and words the middle one as "between 1 August 1997 and 30 April 2014" [CFA selecting]. For pre-1997 homes the CFA says "you can use any type of smoke alarm including battery-powered smoke alarms" and recommends 10-year long-life battery alarms.

Do existing Victorian homes have to be interconnected?

Not by any official rule I could find. Every official source ties compulsory interconnection to homes "constructed, largely renovated, or extended after 1 May 2014" (FRV) or "constructed, or significantly renovated after 1 May 2014" (CFA) [FRV] [CFA types]. For older homes it is a strong recommendation, not a legal requirement.

This is a big difference from Queensland, where every home must have interconnected photoelectric alarms by 1 January 2027. If you are moving between the two states, or own property in both, see the Queensland rules.

What do FRV and the CFA recommend beyond the law?

Victoria's fire services are more ambitious than the minimum. They recommend:

  • An alarm in every bedroom and living area. FRV explains why: "when a fire starts in a bedroom with doors closed, the smoke alarm outside the bedroom will not activate" [FRV].
  • Interconnection. The BPC says alarms "should also be interconnected, so that when any alarm activates, all smoke alarms will sound" [BPC].
  • Long-life batteries. CFA and FRV recommend alarms powered by a ten-year lithium battery that lasts the life of the alarm [BPC].

FRV rates options as good, better and best. Its "best" option is a "wireless interconnected smoke alarm with a 10-year lithium backup battery" [FRV]. The BPC notes that wireless interconnected alarms powered by a ten-year lithium battery "can be easily installed without requiring an electrician", while hardwired ones should be installed by an electrician [BPC]. That makes upgrading an older Victorian home much cheaper than many people expect. See wireless vs hardwired.

Photoelectric or ionisation in Victoria?

Victoria does not mandate a sensor type for existing homes, and the fire services compare the types rather than naming one winner. The CFA says photoelectric alarms are better at detecting smoke from smouldering fires (such as cigarettes, synthetic furnishings and electrical overloading) and are less likely to cause false alarms, ionisation alarms are better with fast-flaming fires, and "dual sensor alarms are quicker to activate than ionisation or photoelectric smoke alarms" [CFA types]. FRV's costings brochure says much the same, adding that dual-sensor alarms "usually cost more but offer better protection" [FRV costings].

One rule the CFA does state firmly: "All the smoke alarms in your home must use the same technology to connect to one another and work properly" [CFA types]. In practice, that means one brand and system across the house. More in photoelectric vs ionisation.

What do Victorian rental providers have to do?

Victoria tightened the rules from 25 November 2025. Consumer Affairs Victoria says annual smoke alarm safety checks became mandatory for all rental properties from that date [CAV], whether the agreement started before, on or after 29 March 2021 [CAV changes]. Section 68AA of the Residential Tenancies Act 1997 now says a rental provider must ensure every smoke alarm is [Vic RTA s 68AA]:

  • correctly installed and in working condition
  • fitted with batteries or replacement batteries
  • tested at least once every 12 months, following the maker's instructions.

Consumer Affairs Victoria adds these points [CAV]:

  • On or before the start of a lease, the rental provider must give the renter written information about how each alarm works, how to test it, and the renter's duty not to tamper with alarms and to report one that isn't working.
  • A smoke alarm that is not working is an urgent repair and must be arranged immediately.
  • If the rental provider doesn't act, the renter can authorise and pay for an urgent repair of up to $2,500, and the rental provider must pay them back within 7 days.
  • A hardwired alarm must be installed by a qualified electrician, "but anyone can change a smoke alarm battery".
  • Rooming houses must have hardwired smoke alarms.

Section 68AA also says testing, repair or replacement of a mains-powered alarm must be done by a suitably qualified person [Vic RTA s 68AA]. For the full comparison with other states, see landlord smoke alarm obligations by state.

What are the penalties in Victoria?

The BPC says "a fine can be imposed on an owner who fails to comply with the smoke alarm requirements of the Building Regulations 2018" [BPC], but it does not give an amount, and I could not find a penalty figure on an official page. Regulation 145 itself carries no penalty line in the current version [Vic Building Regs r 145], and the new rental section 68AA has no penalty attached [Vic RTA s 68AA]. I have left out any dollar figure rather than guess.

How should I look after alarms in Victoria?

FRV and the CFA give the same routine [FRV] [CFA maintenance]:

  • Test every month by pressing the test button until the alarm sounds.
  • Clean at least once a year with a vacuum cleaner or by dusting the cover.
  • Replace 9 volt batteries every year.
  • Replace every alarm after 10 years. FRV says it is best to replace them with hardwired, interconnected alarms. The CFA notes most warranties expire at 10 years and that hardwired alarms "must be replaced by a licensed electrician".

The CFA also says alarms are not needed in kitchens, laundries or bathrooms, where they are likely to cause false alarms [CFA installation]. See where to install smoke alarms and how to test and clean them.

Who do I contact in Victoria?

For fire safety questions, Fire Rescue Victoria (metropolitan Melbourne) or the CFA (regional Victoria). For building rules, the Building and Plumbing Commission. For rental questions, Consumer Affairs Victoria. Their pages are linked in the sources below.

Sources

Every source below was read on the official page. Last checked: November 2026.

  1. Building and Plumbing Commission (Victoria): Smoke alarms (safety guide)
  2. Victorian Legislation: Building Regulations 2018 (Vic), authorised version 028, regulation 145 (PDF)
  3. Fire Rescue Victoria: Smoke alarms (page updated 9 September 2026)
  4. Fire Rescue Victoria: Smoke alarm power supply and costings (PDF, May 2026)
  5. Country Fire Authority (Victoria): Selecting a smoke alarm
  6. Country Fire Authority (Victoria): Types of smoke alarms
  7. Country Fire Authority (Victoria): Smoke alarm installation
  8. Country Fire Authority (Victoria): Smoke alarm maintenance
  9. Consumer Affairs Victoria: Smoke alarms and fire safety (renting)
  10. Consumer Affairs Victoria: New changes to rental laws
  11. Victorian Legislation: Residential Tenancies Act 1997 (Vic), authorised version 111, section 68AA (PDF)