General information, not legal or electrical advice. Check the current rules with your state authority and use a licensed electrician for any hardwired work.

Short answer

In the ACT, a landlord cannot sign a lease unless AS 3786 smoke alarms are installed on every storey and in the hallways serving bedrooms. Battery or hardwired alarms are both allowed in rentals. ACT Fire & Rescue says hardwired alarms are legally required in houses built after 1 November 1994, and recommends interconnected alarms in every bedroom. I found no ACT law requiring photoelectric or interconnected alarms in existing homes, and no smoke alarm rule tied to selling.

The ACT's written law on smoke alarms is mostly about rentals. For owner-occupied homes, the main guide is ACT Fire & Rescue, part of the Emergency Services Agency (ESA). This page separates what is in the legislation from what is fire service advice, because in the ACT the two are easy to blur.

What smoke alarms does an ACT rental need?

Section 11B of the Residential Tenancies Act 1997 says a lessor "must not enter into a residential tenancy agreement" unless smoke alarms are installed and they, and their installation, meet the regulation [ACT RTA 1997]. The standard tenancy terms then require the lessor to "install and maintain smoke alarms in the premises" (clause 53A) [ACT RTA 1997].

Section 1B of the Residential Tenancies Regulation 1998 sets the details [ACT RT Regulation 1998]. Each alarm must:

  • comply with AS 3786
  • be functional
  • be installed on or near the ceiling.

It may be battery-operated or hardwired. And alarms must be installed [ACT RT Regulation 1998]:

  • on each storey with a bedroom, in every corridor or hallway associated with a bedroom
  • if there is no corridor, between each part with a bedroom and the rest of the premises
  • on each storey without a bedroom.

The ACT Government's renting page says the same in plain terms, and adds that "the landlord is responsible for making sure working smoke alarms are installed at the start of the tenancy" [act.gov.au renting].

Who changes the batteries in an ACT rental?

The tenant. This is different from NSW, Victoria and Queensland. Standard term 63A says: "The tenant must replace the battery in a smoke alarm installed in the premises whenever necessary" [ACT RTA 1997], and the ACT Government says "the tenant is responsible for checking and replacing the battery in the smoke alarm" [act.gov.au renting]. The landlord still has to install and maintain the alarms themselves. For a full comparison, see landlord obligations by state.

What about owner-occupied homes in the ACT?

ACT Fire & Rescue says "working smoke alarms are compulsory in the ACT", and that hardwired smoke alarms are "legally required in houses built after 1 November, 1994", while homes built before November 1994 "can have battery or wired alarms" [ACT ESA]. It also says "a hard-wired alarm must be replaced with a hard-wired alarm" [ACT ESA].

Do ACT alarms have to be photoelectric?

Not by law. The rental regulation accepts any AS 3786 alarm, and AS 3786 covers both photoelectric and ionisation types [ACT RT Regulation 1998]. ACT Fire & Rescue encourages the switch: "If you have an ionisation smoke alarm that is approaching its expiry date (usually 10 years) or it has become faulty, ACT Fire & Rescue encourages you to replace it with a photoelectric smoke alarm" [ACT ESA]. See photoelectric vs ionisation.

What does ACT Fire & Rescue recommend?

  • "ACTF&R recommend that all houses have an interconnected smoke alarm in each bedroom, in each bedroom corridor and on each level of a property" [ACT ESA].
  • "Wherever possible, hard-wired and interconnected smoke alarms". Alternatively, "alarms with a 10-year embedded lithium-ion battery are a great choice for DIY" [ACT ESA].
  • Alarms on or near the ceiling in bedrooms or in the corridor leading to bedrooms, installed as the maker instructs and in line with the National Construction Code [ACT ESA].

ESA explains interconnection as smoke alarms that "communicate with each other so that if one smoke alarm activates all the smoke alarms in the home go off, giving all residents the best chance of getting out safely before they are overcome by smoke" [ACT ESA]. More in interconnected smoke alarms explained.

Do I need compliant smoke alarms to sell a house in the ACT?

I found no ACT rule tying smoke alarms to a sale. The Civil Law (Sale of Residential Property) Act 2003 does not mention smoke alarms [ACT sale Act]. That is different from Queensland, Western Australia and South Australia, which all have sale-time rules. The general ACT rules for the type of home still apply, and a buyer who plans to rent the property out will need alarms that meet the rental regulation before signing a lease. See selling a house.

How should ACT smoke alarms be maintained?

ACT Fire & Rescue recommends [ACT ESA]:

  • Test monthly.
  • Vacuum dust off alarms every six months.
  • Replace lead or alkaline batteries every 12 months.
  • Replace smoke alarms every 10 years, regardless of the power source.
  • Consult a licensed electrician where needed and follow the maker's instructions.

See how to test and clean smoke alarms.

ACT compared with NSW

Canberra residents often read NSW pages by mistake. The ACT and NSW have similar minimum locations (each storey, near bedrooms) and neither requires photoelectric or interconnected alarms in existing homes. The big differences are in rentals: NSW landlords must check alarms every year and replace batteries, while in the ACT the tenant replaces batteries. See the NSW rules.

Sources

Every source below was read on the official page. Last checked: November 2026.

  1. ACT Legislation Register: Residential Tenancies Act 1997 (ACT), s 11B and standard terms 53A and 63A (PDF)
  2. ACT Legislation Register: Residential Tenancies Regulation 1998 (ACT), s 1B (PDF)
  3. ACT Government: During a tenancy
  4. ACT Emergency Services Agency (ACT Fire & Rescue): Smoke alarms
  5. ACT Legislation Register: Civil Law (Sale of Residential Property) Act 2003 (PDF)